When you are using multi-version of Xilinx hardware servers on a computer, you may find out some conflicts:
1. port conflict
The default port for the Xilinx hardware server is 3121. If two versions of hardware server working on a computer, the ports have to be different
In this case, you can use -stcp::<port> argument to change the port number
hw_server.bat -S -stcp::3122
2. XVC(Xilinx Virtual Cable) conflict
If one hardware server is working for a device, then the other hardware server doesn't work for another device. It is because the first one uses two devices even if one of them is not necessary.
Therefore you need to map the server and device.
For this, the cable id is needed. you can use -e "set jtag-port-filter <cable_id>" argument to filter specific cable
hw_server.bat -e "set jtag-port-filter Xilinx/TUL/1234-tulA"
'Programming > Xilinx' 카테고리의 다른 글
SDK pointer vs array (0) | 2021.12.04 |
---|---|
ERROR: [USF-XSim-62] 'elaborate' step failed with errors (0) | 2021.01.14 |
Vivado [Opt 31-67] Issue (0) | 2020.12.30 |
ZCU102 Evaluation Kit SODIMM issue (0) | 2020.12.21 |
UART terminal on remote RaspberryPI (0) | 2020.12.18 |